2.2.364. SPN 5372, FMI 0, WG Actuator 1 temperature alert (ERROR 1)ΒΆ
Description
The wastegate actuator temperature is too high.
Possible causes are:
- The wastegate actuator water cooling system is defective.
- The cooling system is not completely filled.
- The cooling system is clogged.
Reaction in EEM
The FC is stored and the warning lamp is activated. The CAN message indicates an active fault.
Solution
First save the error log and then do the procedure that follows:
- Examine that the wastegate actuator cooling pipes are not squashed or blocked.