2.2.243. SPN 4376, FMI 4, DEF pump direction valve: Low side short circuit to GROUNDΒΆ
Description
The EEM monitoring system has detected a short circuit to ground on the DEF pump direction valve low side.
Possible causes are:
- The DEF supply module direction valve wiring is defective. (Shorted to ground.)
- The DEF supply module is defective.
Reaction in EEM
The FC is stored and the warning lamp is activated. The CAN message indicates an active fault.
NOTE: The present fault is classified as an emission related fault. Engine power is reduced after a certain time defined by an authority.
Solution
First save the error log and then do the procedure that follows:
- Examine the DEF supply module direction valve wiring, the connectors and the contact surfaces of the connector pins (possible oxidation).
- Test the operation with another DEF supply module to see if the supply module is defective.
See Supply module sensor for reference.