2.2.148. SPN 3361, FMI 14, DEF dosing valve: Current abnormal behaviourΒΆ
Description
The EEM monitoring system has detected abnormal behavior on the DEF dosing valve current.
Possible causes are:
- The DEF dosing valve wiring is defective.
- The DEF dosing valve is defective.
Reaction in EEM
The FC is stored and the warning lamp is activated. The CAN message indicates an active fault.
NOTE: The present fault is classified as an emission related fault. Engine power is reduced after a certain time which is defined by an authority.
Solution
First save the error log and then do the procedure that follows:
- Examine the DEF dosing valve wiring, the connectors and the contact surfaces of the connector pins (possible oxidation). (see Dosing module)
- Test the operation with another dosing valve to see if the valve is defective.