2.2.237. SPN 4375, FMI 3, DEF pump motor: Control signal short circuit to HIGH SOURCE.ΒΆ
Description
The EEM monitoring system has detected a short circuit to the DEF pump control signal.
Possible causes are:
- The DEF supply module wiring is defective. (Shorted to high source.)
- The DEF supply module is defective.
Reaction in EEM
The FC is stored and the warning lamp is activated. The CAN message indicates an active fault.
NOTE: The present fault is classified as an emission related fault. Engine power is reduced after a certain time defined by an authority.
Solution
First save the error log and then do the procedure that follows:
- Examine the DEF supply module wiring, the connectors and the contact surfaces of the connector pins (possible oxidation).
- Test the operation with another DEF supply module to see if the supply module is defective.
See Supply module sensor for reference.