2.2.194. SPN 4334, FMI 3, DEF pressure sensor: Electrical signal above normal, possible reason is open circuit.ΒΆ
Description
The measured DEF supply module pressure sensor signal is above the normal operating range.
Possible causes are:
- The DEF supply module wiring is defective. (Shorted to high source or open circuit.)
- The DEF supply module is defective.
Reaction in EEM
The FC is stored and the warning lamp is activated. The CAN message indicates an active fault.
NOTE: The present fault is classified as an emission related fault. Engine power is reduced after a certain time defined by an authority.
Solution
First save the error log and then do the procedure that follows:
- Examine the DEF supply module wiring, the connectors and the contact surfaces of the connector pins (possible oxidation).
- Test the operation with another DEF supply module to see if the supply module is defective.
See Supply module sensor for reference.