3.2.483. SPN 677, FMI 3, Start relay low side voltage above normal or short to high SOURCEΒΆ
Description
The start relay low side voltage is above the normal operating range.
Possible causes are:
- The start relay wiring is defective. (Shorted to high source.)
- The start relay is defective.
Reaction in EEM
The FC is stored and the warning lamp is activated. The CAN message indicates active fault.
Solution
First save the error log and then erase it. Restart the ECU after erasing the error log. If the fault occurs again during the next driving cycle, check the following paths:
- Check the start relay wiring, the connectors and the contact surfaces of the connector pins (possible oxidation). (see Start Relay)
- Check the operation with another start relay to see if the start relay is defective.