3.2.103. SPN 2659, FMI 1, EGR circulation mass flow rate below normalΒΆ
Description
The EEM monitoring system has detected that the EGR circulation rate is below normal.
Possible causes are:
- A possible leakage in the EGR piping.
- The EGR pipe is blocked.
- The shaft between the EGR actuator and the valve is defective.
- The valve is stuck.
- The EGR actuator is defective.
Reaction in EEM
The FC is stored and the warning lamp is activated. The CAN message indicates active fault.
Solution
First save the error log and then erase it. Restart the ECU after erasing the error log. If the fault occurs again during the next driving cycle, check the following paths:
- Check the EGR installation visually to detect the possible leakage.
- Check that the shaft between the actuator and the valve is in order. The shaft should be movable when the ignition and the ECU are shut OFF.
- Check the EGR actuator wiring, the connectors and the contact surfaces of the connector pins (possible oxidation).
- Check the operation with another EGR actuator.
See Exhaust gas temperature sensor for reference.