2.2.360. SPN 522463, FMI 12, Upstream NOx sensor: Control unit detects an open circuit between sensor and SCU.ΒΆ
Description
Open circuit in sensor probe.
Possible causes are:
- The NOx sensor is defective.
Reaction in EEM
The FC is stored and the warning lamp is activated. The CAN message indicates an active fault.
NOTE: The present fault is classified as an emission related fault. Engine power is reduced after a certain time which is defined by an authority.
Solution
First save the error log and then do the procedure that follows:
- Check the NOx-sensor operation with service tool NOx-sensor test.
- Check the operation with another NOx sensor to see if the sensor is defective.
See NOx sensor for reference.