2.2.197. SPN 4334, FMI 8, SCR system: DEF pressure reduction failureΒΆ
Description
The EEM monitoring system has detected an SCR system ERROR. The SCR system cannot perform the pressure reduction.
Possible causes are:
- The DEF supply module inlet connector is blocked.
- the DEF inlet line hose is defective.
- The DEF supply module main filter is defective.
- The DEF supply module is defective.
Reaction in EEM
The FC is stored and the warning lamp is activated. The CAN message indicates an active fault.
NOTE: The present fault is classified as an emission related fault. Engine power is reduced after a certain time which is defined by an authority.
Solution
First save the error log and then do the procedure that follows:
- Change the DEF supply module main filter.
- Change the DEF supply module inlet connector.
- Examine the DEF inlet line hose by visually to detect any mechanical failure e.g. hose is flattened.
- Remove the DEF inlet line hose to detect blockage in the hose.