2.2.151. SPN 3361, FMI 4, DEF pump direction valve: Low side short circuit to GROUNDΒΆ
Description
The EEM monitoring system has detected a short circuit to the ground on the DEF dosing valve low side control circuit.
Possible causes are:
- The DEF dosing valve wiring is defective.
- The DEF dosing valve is defective.
Reaction in EEM
The FC is stored and the warning lamp is activated. The CAN message indicates an active fault.
NOTE: The present fault is classified as an emission related fault. Engine power is reduced after a certain time which is defined by an authority.
Solution
First save the error log and then do the procedure that follows:
- Examine the DEF dosing valve wiring, the connectors and the contact surfaces of the connector pins (possible oxidation). (see Dosing module)
- Test the operation with another dosing valve to see if the valve is defective.