2.2.19. SPN 107, FMI 18, Air filter pressure: Pressure BELOW NORMAL.ΒΆ
Description
The air filter pressure is below normal operation range.
Possible causes are:
- The air filter is blocked.
- The air filter pressure sensor wiring is defective.
- The air filter sensor is defective.
Reaction in EEM
The FC is stored and the warning lamp is activated. The CAN message indicates an active fault.
Solution
- Change the air filter.
- Examine the air filter pressure sensor wiring, the connector and the contact surfaces of the connector pins (possible oxidation).
- Try the operation with another air filter pressure sensor to see if the air filter pressure sensor is defective.