2.2.17. SPN 1076, FMI 6, MPROP control: High side short circuit to GROUND.ΒΆ
Description
The EEM monitoring system has detected a short circuit to ground on the high pressure pump control (MPROP) high side.
Possible causes are:
- The solenoid valve connector is defective.
- The solenoid valve wiring is defective.
- The solenoid valve is defective.
Reaction in EEM
The FC is stored and the warning lamp is activated. The CAN message indicates an active fault.
Solution
First save the error log and then do the procedure that follows:
- Examine the solenoid valve wiring, the connectors and the contact surfaces of the connector pins (possible oxidation).
- Measure the high side from the wiring terminal to the engine ground, to see if there is a battery short circuit.
- Test the operation with another MPROP solenoid valve to see if the solenoid valve is defective.
See Common Rail high Pressure Pump (MPROP) for reference.