4.2.306. SPN 655, FMI 13, Solenoid valve 5, Calibration value missingΒΆ

Description

The EEM monitoring system has detected that calibration is missing from solenoid valve 5.

Reaction in EEM

The FC is stored and the warning lamp is activated. Engine power is heavily reduced (Degradation Level 3). The CAN message indicates active fault.

Solution

Contact a local service representative. A new injection calibration can be done by using the engine service tool.