4.2.180. SPN 4376, FMI 5, DEF pump direction valve low side current below normal or open circuitΒΆ
Description
Measured DEF pump direction valve low side current is below normal or open circuit.
Possible causes are:
- The DEF supply module wiring is defective. (Shorted to low side or open circuit)
- The DEF supply module is defective.
Reaction in EEM
The FC is stored and the warning lamp is activated. The CAN message indicates active fault.
NOTE: The present fault is classified as an emission related fault. Engine power will be reduced after a certain time defined by an authority.
Solution
First save the error log and then erase it. Restart the ECU after erasing the error log. If the fault occurs again during the next driving cycle, check the following paths:
- Check the DEF pump wiring, the connectors and the contact surfaces of the connector pins (possible oxidation). Measure the cable from the pump connector to the ECU connector to detect the faulty cable.
- Check the operation with another DEF supply module to see if the supply module is defective.