4.2.153. SPN 4354, FMI 3, DEF suction line heater relay low side (line relay) open circuitΒΆ
Description
EEM4 monitoring system has detected open circuit on DEF suction line heater relay.
Possible causes are:
- The DEF suction line heater relay wiring is defective.
- The DEF suction line heater is defective
Reaction in EEM
The FC is stored and the warning lamp is activated. The CAN message indicates active fault.
NOTE: The present fault is classified as an emission related fault. Engine power will be reduced after a certain time defined by an authority.
Solution
First save the error log and then clear it. After clearing, restart the ECU. If the fault occurs again during the next driving cycle, check the following paths:
- Check the DEF suction line heater relay wiring, the connectors and the contact surfaces of the connector pins (possible oxidation).
- Check the operation with another heater relay to see if the relay is defective.