4.2.149. SPN 4346, FMI 3, DEF pressure line heater control circuit short circuit to high SOURCEΒΆ
Description
The EEM4 monitoring system has detected a short circuit on the DEF pressure line heater control circuit.
Possible causes are:
- The DEF pressure line heater wiring is defective. (Shorted to high source.)
- The DEF pressure line is defective
Reaction in EEM
The FC is stored and the warning lamp is activated. The CAN message indicates active fault.
NOTE: The present fault is classified as an emission related fault. Engine power will be reduced after a certain time defined by an authority.
Solution
First save the error log and then erase it. Restart the ECU after erasing the error log. If the fault occurs again during the next driving cycle, check the following paths:
- Check the DEF pressure line heater wiring, the connectors and the contact surfaces of the connector pins (possible oxidation).
- Check the operation with another heater relay to see if the relay is defective.