4.2.92. SPN 2791, FMI 6, EGR Valve overloadΒΆ

Description

EGR actuator duty cycle is above safe operating level. Error will heal when duty returns to the safe area.

Possible causes are:

  • The EGR actuator is defective
  • The CAN bus is defective

Reaction in EEM

The FC is stored and the warning lamp is activated. The CAN message indicates active fault.

Solution

First save the error log and then erase it. Restart the ECU after erasing the error log. If the fault occurs again during the next driving cycle, check the following paths:

  • Check the EGR actuator assembly to detect the defective control shaft.
  • Check the operation with another EGR actuator to see if the actuator is defective.