4.2.28. SPN 1083, FMI 3, Auxiliary analog input 1 voltage above normal or open circuitΒΆ
Description
The measured auxiliary analog input 1 signal voltage is above the normal operating range.
Possible causes are:
- The analog device output is shorted to HIGH SOURCE.
- The analog device is defective.
Reaction in EEM
The FC is stored and the warning lamp is activated. The CAN message indicates active fault.
Solution
- Check the analog device wiring, the connectors and the contact surfaces of the connector pins (possible oxidation)
- Check the operation with another analog device to see if the analog device is defective.