3.2.315. SPN 520245, FMI 31, ECU 2 Injector bank 2 short circuitΒΆ

Description

The EEM4 monotoring system has detected more than one cylinder error. If a cylinder error occurs in one bank, cylinder specific error is reported. If more than one cylinder error on one bank occurs at the same time, these errors are compiled automatically and are detected as a bank error.

Possible causes are in the 12-cyl engine:

  • The solenoid valve 9 is defective.
  • The solenoid valve 10 is defective.

Reaction in EEM

The FC is stored and the warning lamp is activated. The CAN message indicates active fault.

Solution

First save the error log and then erase it. Restart the ECU after erasing the error log. If the fault occurs again during the next driving cycle, check the following paths:

  • Check the solenoid valve 9 and 10 wiring, the connectors and the contact surfaces of the connector pins (possible oxidation).
  • Measure the solenoid valve 9 and 10 low side to the engine ground, to see if there is a short circuit to bat.
  • Measure between the solenoid valve 9 and 10 cables, to see if there is a short circuit between the cables.