3.2.165. SPN 3511, FMI 31, 5Vdc Supply 3 voltage out of rangeΒΆ
Description
The EEM4 monitoring system has detected an internal failure in the 5 V sensor supply.
Possible causes are:
The fan wiring is defective. The fan is defective. The rail pressure sensor wiring is defective. The rail pressure sensor is defective.
Reaction in EEM
The FC is stored and the warning lamp is activated. The CAN message indicates active fault.
Solution
First save the error log and then erase it. Restart the ECU after erasing the error log. If the fault occurs again during the next driving cycle, check the following paths:
- Check the rail pressure sensor for a short circuit to ground.
- Check the fan speed circuit wiring and the power supply.
- Check the fan speed circuit the connectors and the contact surfaces of the connector pins. (possible oxidation).
- If no short circuit is found, the reason might be a defective ECU.
- Check the ECU operation with another EEM4 controller. If the system is functional and the fault is not active with the replacement ECU, then the original ECU is defective.