3.2.55. SPN 1189, FMI 7, WG Actuator 2 motor unpowered due fault condition (ERROR 5)ΒΆ
Description
The WG 2 actuator electric motor is faulty.
Possible causes are:
- The WG 2 actuator motor has shorted to ground, battery or across the motor.
- The WG 2 actuator is defective.
Reaction in EEM
The FC is stored and the warning lamp is activated. Engine power will be reduced (Degradation Level 1). The CAN message indicates active fault.
Solution
First save the error log and then erase it. Restart the ECU after erasing the error log. If the fault occurs again during the next driving cycle, check the following paths:
- Check the WG 2 actuator wiring, the connectors and the contact surfaces of the connector pins (possible oxidation).
- Check the operation with another WG actuator to see if the actuator is defective.